Plenty of extractor fans spin and move almost no air. Here is how to test yours and what to fix, from free checks to a proper installation.
Showers, cooking and kettles put a lot of moisture into the air in a very short time. A good extractor fan removes it at the source, before it spreads and condenses on cold walls. A weak fan, a fan that vents into the loft or a recirculating cooker hood does not, and the mould that shows up around the bathroom ceiling is the result.
Hold a sheet of tissue to the fan grille: if it does not stick, the fan is moving too little air. Check the duct goes outside, run the fan during and after showering and cooking, and use a cooker hood that vents outdoors. New-work ventilation guidance sets 15 litres per second for a bathroom and 30 for a kitchen hood venting outside.
Many Victorian terraces had the bathroom added later in a rear extension or converted from a bedroom, often with a small window and a fan squeezed onto an internal wall. In flats and internal bathrooms the duct run is long and the fan is easy to undersize. Steam that cannot leave goes into the house and settles on the coldest surface, which in a solid-wall terrace is the nearest outside wall.
Work down the rungs in order. Most problems are solved on rungs 1 to 3, and each rung says plainly when the next one is not needed.
Dust and grease choke fans, so clean the grille and fan housing with the power off. Cook with lids on pans, and wipe down tiles and windows after a shower. A fan with a run-on timer or humidity sensor removes the need to remember. Keep kitchen and bathroom doors shut so that moisture does not drift into cooler rooms.
For new fans, ask for the extract rate in litres per second. The current ventilation guidance for new work sets 15 l/s for bathrooms and 30 l/s for a kitchen hood venting outside, or 60 l/s where there is no hood, and the installer should size the duct and the fan to the run, using short, insulated, rigid duct that falls gently to the outside. Ask for a humidistat or run-on timer, and a backdraught shutter so cold air does not blow back in.
Where the room cannot be fitted with a fan, or moisture builds up throughout the home across the winter, a loft-mounted dehumidifier such as Dryzen may suit an owner-occupied home with a loft. It covers up to 150 m2 per unit and extracts up to 12 litres a day, with insulated ductwork to the central area or stairway only. It is not a bathroom or cooker extractor and does not replace one.
Run it during the shower and for a while afterwards, until the mirror and windows have cleared. A run-on timer or humidity sensor removes the guesswork.
No. It filters grease and some odours but returns the moist air to the room. A hood that vents outside removes moisture.
No. A fan removes moisture at source. A dehumidifier lowers the moisture level across the home. They do different jobs.
Book a free survey and we will tell you honestly whether your damp is the kind a Dryzen system helps with, or whether you need a roofer, a gutter repair or a damp specialist first. Our Gold Pack membership (£199 per year) includes remote humidity monitoring and a yearly onsite system check: we alert you if there are any issues with your home or the dehumidifier.
Book a Free SurveySources: GOV.UK, Approved Document F (ventilation), volume 1; GOV.UK, Understanding and addressing the health risks of damp and mould in the home; Property Care Association, common damp-proofing problems. This guide is general information, not a survey of your home.